Ultrasound and Its Medical and Industrial Applications
Multiple Choice Questions
1 Ultrasound refers to sound waves with frequencies above approximately:
(a) 20 Hz
(b) 20 kHz
(c) 200 Hz
(d) 2 kHz
2 Ultrasound is classified as:
(a) Ionising electromagnetic radiation
(b) Nuclear radiation
(c) Mechanical wave motion
(d) Static electricity
3 Ultrasound cannot propagate through:
(a) A perfect vacuum
(b) Water
(c) Soft tissue
(d) Steel
4 Ultrasound transducers commonly operate using:
(a) Photoelectric emission
(b) Radioactive decay
(c) Chemical combustion
(d) The piezoelectric effect
5 The direct piezoelectric effect involves generation of:
(a) Electrical charge in response to mechanical stress
(b) Nuclear energy
(c) Visible light only
(d) Gravitational waves
6 The converse piezoelectric effect involves:
(a) Conversion of heat into mass
(b) Mechanical deformation in response to an electric field
(c) Chemical decomposition only
(d) Radioactive decay
7 Medical diagnostic ultrasound commonly uses frequencies in the:
(a) Single-digit hertz range
(b) Audible range only
(c) Megahertz range
(d) Gamma-ray range
8 Compared with lower-frequency ultrasound, higher-frequency ultrasound generally provides:
(a) Greater penetration and poorer resolution
(b) No reflection
(c) Infinite penetration
(d) Better resolution but reduced penetration
9 Ultrasound imaging primarily relies on:
(a) Detection of reflected acoustic pulses
(b) Detection of radioactive particles
(c) Absorption of visible light
(d) Nuclear magnetic resonance
10 Acoustic impedance is commonly calculated as:
(a) c/ρ
(b) ρc
(c) ρ/c
(d) ρ + c
11 Ultrasound reflection at a tissue boundary depends strongly on:
(a) Tissue colour
(b) Electrical resistance alone
(c) Differences in acoustic impedance
(d) Atomic number alone
12 Ultrasound gel is applied principally to:
(a) Increase ionising radiation
(b) Cool the entire body
(c) Produce radioactive tracers
(d) Reduce air gaps and improve acoustic coupling
13 Ultrasound examination of the heart is called:
(a) Echocardiography
(b) Electroencephalography
(c) Spirometry
(d) Radiography
14 Doppler ultrasound is particularly useful for evaluating:
(a) Bone mineral composition directly
(b) Blood flow
(c) Electrical resistance
(d) Blood group directly
15 Doppler ultrasound measures:
(a) Radioactive half-life
(b) Chemical concentration directly
(c) Frequency shifts associated with motion
(d) Gravitational acceleration
16 A conventional B-mode ultrasound image represents:
(a) Electrical activity only
(b) A chemical spectrum
(c) A temperature graph only
(d) Echo amplitudes as image brightness
17 M-mode ultrasound is particularly useful for displaying:
(a) Motion of structures over time
(b) Atomic structure
(c) Blood chemistry
(d) Electrical resistance
18 A-mode ultrasound displays:
(a) A three-dimensional colour photograph
(b) Echo amplitude against depth or time
(c) X-ray absorption
(d) Magnetic field strength
19 Obstetric ultrasound is commonly used to assess:
(a) Maternal blood group directly
(b) DNA sequence directly
(c) Foetal growth and anatomical development
(d) Atomic mass
20 Ultrasound examination of abdominal organs may include the:
(a) Retina only
(b) External ear only
(c) Tooth enamel only
(d) Liver, gallbladder and kidneys
21 A major advantage of diagnostic ultrasound over conventional X-ray imaging is:
(a) Absence of ionising radiation
(b) Unlimited penetration through bone
(c) Perfect imaging of every tissue
(d) Elimination of all clinical risks
22 Conventional ultrasound imaging through air-filled lungs is limited principally because:
(a) Air has infinite density
(b) Air–tissue interfaces strongly reflect sound
(c) Ultrasound is absorbed by gravity
(d) Sound has no wavelength
23 Ultrasound transmission through adult skull bone is often limited by:
(a) Complete absence of mechanical properties
(b) Zero acoustic impedance
(c) Attenuation and reflection
(d) Nuclear radiation
24 The assumed average sound speed in soft tissue for many ultrasound systems is:
(a) 343 m/s
(b) 154 m/s
(c) 15,400 m/s
(d) 1,540 m/s
25 An ultrasound pulse returns from a tissue boundary after 200 microseconds. At 1,540 m/s, the boundary depth is:
(a) 15.4 cm
(b) 30.8 cm
(c) 1.54 cm
(d) 154 cm
26 A 5 MHz ultrasound wave travelling at 1,540 m/s has wavelength approximately:
(a) 3.08 mm
(b) 0.308 mm
(c) 30.8 mm
(d) 0.0308 mm
27 The loss of acoustic wave intensity during propagation is called:
(a) Polarisation
(b) Magnetisation
(c) Attenuation
(d) Ionisation
28 Acoustic attenuation in soft tissue generally:
(a) Decreases to zero as frequency increases
(b) Is independent of frequency
(c) Occurs only in a vacuum
(d) Increases with frequency
29 The ability to distinguish two reflectors along the direction of beam propagation is:
(a) Axial resolution
(b) Electrical conductivity
(c) Angular momentum
(d) Thermal equilibrium
30 Lateral resolution depends strongly on:
(a) Radioactive half-life
(b) Ultrasound beam width
(c) Atmospheric pressure alone
(d) Blood group
31 High-intensity focused ultrasound is abbreviated as:
(a) HFIR
(b) HIFR
(c) HIFU
(d) HIUV
32 HIFU is used in selected medical procedures to:
(a) Produce ionising X-rays
(b) Measure atmospheric humidity
(c) Generate radio broadcasts
(d) Concentrate acoustic energy within targeted tissue
33 Extracorporeal shock-wave lithotripsy employs focused acoustic shock waves to:
(a) Fragment certain urinary stones
(b) Determine blood group
(c) Replace all surgical procedures
(d) Measure body temperature
34 Ultrasound-guided procedures can assist clinicians in:
(a) Identifying chemical elements directly
(b) Visualising anatomical structures and instrument position
(c) Eliminating the need for clinical training
(d) Measuring gravitational force
35 Acoustic cavitation involves:
(a) Formation of electromagnetic fields
(b) Radioactive transformation
(c) Formation and oscillation or collapse of bubbles in a liquid
(d) Production of visible light only
36 Ultrasonic cleaning commonly relies on:
(a) Magnetic induction alone
(b) Nuclear radiation
(c) Electrostatic charging only
(d) Acoustic cavitation
37 Ultrasonic non-destructive testing is used to:
(a) Detect internal material defects without intentionally damaging the component
(b) Melt every inspected object
(c) Measure colour alone
(d) Determine biological age
38 Pulse-echo ultrasonic testing detects defects through:
(a) Chemical staining
(b) Reflected sound signals
(c) Visible-light emission only
(d) Radioactive decay
39 Ultrasonic thickness measurement requires knowledge of:
(a) Surface colour
(b) Electrical charge alone
(c) Sound speed in the material and travel time
(d) Atmospheric humidity alone
40 A pulse travels through a metal plate and returns after 10 microseconds. At 6,000 m/s, the plate thickness is:
(a) 60 mm
(b) 6 mm
(c) 300 mm
(d) 30 mm
41 Ultrasonic welding joins materials using:
(a) High-frequency mechanical vibrations under appropriate pressure
(b) Gamma radiation
(c) Gravitational force
(d) Photosynthesis
42 Ultrasonic flow meters are used to measure:
(a) Electrical capacitance only
(b) Fluid flow
(c) Atomic mass
(d) Magnetic pole strength
43 An ultrasonic level sensor determines liquid level using:
(a) Chemical decomposition
(b) Nuclear decay
(c) Acoustic travel time
(d) Optical colour alone
44 An ultrasonic distance sensor generally calculates distance using:
(a) Frequency alone
(b) Temperature alone
(c) Electrical voltage alone
(d) Sound speed and echo travel time
45 Ultrasonic humidifiers produce fine water droplets using:
(a) High-frequency mechanical vibrations
(b) Nuclear reactions
(c) Magnetic levitation alone
(d) Radioactive particles
46 Which animals are well known for ultrasonic echolocation?
(a) All reptiles
(b) Many bats and toothed whales
(c) All insects
(d) None of these
47 The thermal index displayed by diagnostic ultrasound equipment provides information concerning:
(a) Radioactive dose
(b) Electrical conductivity
(c) Potential tissue heating
(d) Atmospheric temperature
48 The mechanical index relates principally to:
(a) Visible-light intensity
(b) Magnetic field strength
(c) X-ray absorption
(d) Potential non-thermal mechanical bioeffects
49 The ALARA principle in diagnostic ultrasound encourages:
(a) Acoustic exposure as low as reasonably achievable while obtaining necessary diagnostic information
(b) Maximum acoustic output for every examination
(c) Unlimited examination duration
(d) Avoidance of all medical imaging
50 Which statement correctly describes ultrasound?
(a) It is identical to X-ray radiation
(b) It has important medical and industrial applications based on mechanical wave propagation
(c) It travels freely through a perfect vacuum
(d) It always produces ionising radiation
Answer Key
1 (b), 2 (c), 3 (a), 4 (d), 5 (a)
6 (b), 7 (c), 8 (d), 9 (a), 10 (b)
11 (c), 12 (d), 13 (a), 14 (b), 15 (c)
16 (d), 17 (a), 18 (b), 19 (c), 20 (d)
21 (a), 22 (b), 23 (c), 24 (d), 25 (a)
26 (b), 27 (c), 28 (d), 29 (a), 30 (b)
31 (c), 32 (d), 33 (a), 34 (b), 35 (c)
36 (d), 37 (a), 38 (b), 39 (c), 40 (d)
41 (a), 42 (b), 43 (c), 44 (d), 45 (a)
46 (b), 47 (c), 48 (d), 49 (a), 50 (b)