Table of Contents
pH, Buffers and Acid-Base Reactions
1. Introduction
The quantitative study of acidity and alkalinity is essential to chemistry, biology, medicine, agriculture and environmental science.
The pH scale provides a logarithmic representation of hydrogen-ion activity, while buffer systems help resist changes in pH.
Acid–base equilibria explain the behaviour of aqueous solutions, physiological fluids, industrial processes and natural water systems.
2. Self-Ionisation of Water
Water undergoes reversible proton transfer between its molecules.
The ion product of water is:
For sufficiently dilute solutions at 25°C:
Pure water therefore has approximately equal hydrogen-ion and hydroxide-ion concentrations of \(10^{-7}\) mol/L at 25°C.
3. Definition of pH
The pH of a solution is defined as the negative base-ten logarithm of hydrogen-ion activity.
For dilute solutions, the numerical hydrogen-ion concentration in mol/L is commonly used as an approximation:
The logarithmic scale was introduced by Søren Peder Lauritz Sørensen in 1909.
4. The pOH Scale
The pOH scale represents hydroxide-ion activity.
The relationship between pH and pOH is:
At 25°C:
This value changes with temperature.
5. Acidic, Neutral and Alkaline Solutions
At 25°C, aqueous solutions are conventionally classified as follows:
| Classification | pH |
|---|---|
| Acidic | Below 7 |
| Neutral | 7 |
| Alkaline | Above 7 |
Neutrality fundamentally means equal hydrogen-ion and hydroxide-ion activities.
The neutral pH changes with temperature because the ion product of water is temperature-dependent.
The familiar pH range of 0–14 is not an absolute limit. Highly concentrated solutions can exhibit pH values outside this range.
6. Logarithmic Nature of pH
Each unit change in pH represents a tenfold change in hydrogen-ion activity.
A solution of pH 3 possesses approximately 100 times the hydrogen-ion activity of a solution of pH 5.
The pH scale therefore represents chemical acidity logarithmically rather than linearly.
7. Approximate pH Values of Common Substances
| Substance | Typical approximate pH |
|---|---|
| Gastric fluid | 1–3 |
| Lemon juice | 2–3 |
| Vinegar | 2–3 |
| Coffee | 4.5–5.5 |
| Milk | 6.4–6.8 |
| Pure water at 25°C | 7 |
| Normal arterial blood | 7.35–7.45 |
| Seawater | Around 8 |
| Baking soda solution | Around 8–9 |
Actual values depend on composition, concentration, temperature and measurement conditions.
8. Calculation of Strong Acid pH
For an idealised dilute solution containing 0.001 mol/L hydrochloric acid:
Therefore:
This approximation assumes extensive dissociation and negligible effects from water self-ionisation and non-ideal activity.
9. Calculation of Strong Base pH
For a 0.01 mol/L sodium hydroxide solution at 25°C:
10. Weak Acid Equilibria
A weak acid undergoes partial dissociation:
Its acid dissociation constant is approximately:
For a weak monoprotic acid of initial concentration \(C\), where dissociation is sufficiently small:
The approximation must be checked against the extent of dissociation.
11. Weak Base Equilibria
A weak base reacts partially with water:
The base dissociation constant is approximately:
For a sufficiently weak base under suitable dilute conditions:
12. pKa and pKb
Acid and base dissociation constants are frequently expressed logarithmically.
A lower pKa generally indicates a stronger acid within the same solvent and specified conditions.
For a conjugate acid–base pair:
At 25°C in water:
13. Buffer Solutions
A buffer solution resists substantial changes in pH when limited quantities of acid or base are added.
Buffers commonly contain a weak acid and its conjugate base, or a weak base and its conjugate acid.
Buffers do not maintain pH absolutely. Their effectiveness depends on composition, concentration and the amount of acid or base introduced.
14. Acidic and Basic Buffer Systems
14.1 Acidic Buffer
An acidic buffer may contain acetic acid and sodium acetate.
The acetic acid provides a weak-acid component, while acetate provides its conjugate base.
14.2 Basic Buffer
A basic buffer may contain ammonia and ammonium chloride.
Ammonia acts as the weak base, while ammonium ions provide its conjugate acid.
15. Mechanism of Buffer Action
In an acetic acid–acetate buffer, added hydrogen ions react with acetate:
Added hydroxide ions react with acetic acid:
These reactions reduce the changes in free hydrogen-ion or hydroxide-ion activity.
16. Henderson–Hasselbalch Equation
For a weak acid and its conjugate base:
In dilute solutions, concentrations are commonly substituted for activities:
When the acid and conjugate base have equal activities:
For an acetate buffer with a conjugate base-to-acid ratio of 10 and pKa of 4.76:
17. Buffer Capacity and Buffer Range
Buffer capacity describes the ability of a buffer to resist pH changes.
Higher total buffer-component concentrations generally provide greater capacity.
A weak acid–conjugate base buffer is commonly effective over a range approximately one pH unit above and below its pKa.
Dilution can leave the component ratio approximately unchanged while reducing buffer capacity.
18. Biological Buffer Systems
18.1 Bicarbonate Buffer System
The bicarbonate system plays an important role in blood acid–base regulation.
The lungs regulate carbon dioxide elimination, while the kidneys contribute to bicarbonate regulation and acid excretion.
18.2 Phosphate Buffer System
The phosphate buffer system involves:
It is important in intracellular fluids and renal acid handling.
18.3 Protein Buffer Systems
Proteins possess functional groups capable of accepting or donating protons.
Haemoglobin contributes to the buffering capacity of blood.
19. Acid–Base Balance in the Human Body
Normal arterial blood pH is approximately 7.35–7.45.
Acidaemia describes an abnormally low blood pH, whereas alkalaemia describes an abnormally high blood pH.
Acidosis and alkalosis refer to physiological processes tending to lower or raise pH respectively.
Respiratory acid–base disturbances primarily involve carbon dioxide regulation. Metabolic disturbances primarily involve non-respiratory changes in acid or bicarbonate balance.
20. Acid–Base Titration
Titration is an analytical technique used to determine the concentration or amount of a substance through reaction with a solution of known concentration.
An acid–base titration commonly involves a standard acid or base and an unknown solution.
20.1 Equivalence Point
The equivalence point occurs when the titrant and analyte have reacted in their stoichiometrically equivalent amounts.
20.2 End Point
The end point is the experimentally observed indication used to identify completion of the titration.
The end point should approximate the equivalence point but is not necessarily identical to it.
21. Titration Curves
A titration curve represents pH as a function of added titrant volume.
| Titration type | Typical equivalence-point behaviour at 25°C |
|---|---|
| Strong acid–strong base | Approximately neutral |
| Weak acid–strong base | Alkaline |
| Strong acid–weak base | Acidic |
| Weak acid–weak base | Depends on relative strengths |
For a simple weak monoprotic acid titrated with a strong base, the pH at the half-equivalence point is approximately equal to the acid’s pKa.
22. Measurement of pH
22.1 Indicators
Chemical indicators provide approximate acidity measurements through colour changes.
22.2 Universal Indicator
Universal indicator combines several indicator substances to provide colour changes across a broad pH range.
22.3 Electronic pH Meter
A pH meter commonly uses a glass electrode and reference electrode to measure an electrical potential related to hydrogen-ion activity.
Accurate measurement requires calibration, appropriate electrode maintenance and consideration of temperature.
23. Environmental Applications
Soil pH influences nutrient availability, microbial activity and crop development.
Aquatic pH affects biological organisms and chemical speciation.
Water-treatment facilities monitor pH to manage corrosion, treatment effectiveness and water quality.
Ocean acidification alters carbonate equilibria and can affect marine organisms that form calcium carbonate structures.
24. Industrial Applications
pH control is important in food processing, pharmaceutical manufacturing, fermentation, wastewater treatment, textile production, electroplating and chemical synthesis.
Buffer solutions support reproducible chemical and biological processes where uncontrolled pH changes would reduce efficiency or product quality.
25. Common Examination Distinctions
| Concept | Distinction |
|---|---|
| pH and pOH | Hydrogen-ion versus hydroxide-ion activity |
| pKa and pH | Acid dissociation property versus solution acidity |
| Buffer pH and buffer capacity | Acidity level versus resistance to added acid or base |
| Equivalence point and end point | Stoichiometric completion versus observed signal |
| Acidosis and acidaemia | Acidifying process versus low blood pH |
| Neutralisation and neutral pH | Chemical reaction versus equal hydrogen-ion and hydroxide-ion activities |
26. Key Takeaways for Exams
-
Water undergoes reversible self-ionisation.
-
The ion product of water depends on temperature.
-
At 25°C, \(K_w\) is approximately \(10^{-14}\).
-
pH is the negative logarithm of hydrogen-ion activity.
-
pOH represents hydroxide-ion activity.
-
At 25°C, pH and pOH sum to approximately 14.
-
Neutral water has pH 7 at 25°C.
-
Neutral pH changes with temperature.
-
The pH scale is logarithmic.
-
A one-unit pH difference represents a tenfold activity difference.
-
pH values are not absolutely restricted to 0–14.
-
Strong-acid pH can often be estimated from concentration.
-
Weak-acid pH depends on dissociation equilibrium.
-
Ka describes acid dissociation.
-
Kb describes base dissociation.
-
Lower pKa generally indicates greater acid strength.
-
Conjugate acid and base constants are related through Kw.
-
Buffers resist limited changes in pH.
-
Acidic buffers commonly contain a weak acid and conjugate base.
-
Basic buffers commonly contain a weak base and conjugate acid.
-
The Henderson–Hasselbalch equation describes buffer pH.
-
Buffer pH equals pKa when component activities are equal.
-
Buffer capacity depends substantially on component concentration.
-
Dilution can reduce buffer capacity.
-
Bicarbonate is an important physiological buffer.
-
Phosphate contributes to intracellular buffering.
-
Haemoglobin contributes to blood buffering.
-
Normal arterial blood pH is approximately 7.35–7.45.
-
Titration determines chemical quantities through stoichiometric reactions.
-
Equivalence points and end points are distinct.
-
Weak-acid–strong-base titrations have alkaline equivalence points.
-
Electronic pH meters require calibration.
-
Soil pH influences agricultural productivity.
-
Acid–base equilibria are fundamental to environmental and biological chemistry.